Qualcast Cobra 32 Lawn Mower User Manual


 
Fault Finding
The following table gives checks and actions that you can perform if your machine does not operate correctly.
If these do not identify/remedy the problem contact your Qualcast approved service agent.
Warning - switch off, remove plug from mains before investigating fault.
Symptom Possible Cause Remedy
Machine fails to operate Power turned off Turn power on
Mains socket faulty Use another socket
Extension cable damaged Inspect cable, replace if damaged
Fuse faulty/blown Replace Fuse
Machine functions Extension cable damaged Inspect cable, replace if damaged
intermittently Machines internal wiring damaged Contact your service agent
Machine leaves Height of cut too low Increase height of cut
ragged finish (see Height of Cut Adjustment)
Cutting blade blunt Replace blade
(see Blade Maintenance)
Underside of machine Clean machine (see After
badly clogged Mowing/Storage)
Blade fitted upside down Refit blade correctly
(see Blade Maintenance)
Cutting blade not Cutting blade obstructed Clear obstruction
rotating Blade nut/bolt loose Tighten blade nut/bolt
Excessive Blade nut/bolt loose Tighten blade nut/bolt
vibration/noise Cutting blade damaged Replace blade
Declaration of Conformity
Measured values determined according to 2000/
14/EC (sound pressure level at a height of 1.60 m,
1 m distance away) and EN 28 662.
Typically the A-weighted noise level of the product is:
sound pressure level 72 dB (A) ; sound power level
83 dB (A).
The typical hand/arm vibration is below 2.5 m/s²
We declare under our sole responsibility, that this
product is in conformity with the following standards
or standardization documents: EN60335,EN 836
according to the provisions of the directives
89/336/EEC, 98/37/EC, 2000/14/EC.
2000/14/EC: The guaranteed sound power level L
Wa is lower than 84 dB (A). Conformity assessment
procedure according to Annex VIII
Notified body: .SRL Sudbury, England
Signed at Stowmarket
Date: 2001