Poulan Pro BVM200VS Blower User Manual


 
Move at _east 10 feet (3 meters) away from
fuel and fueling site before starting engine.
Always store gasoline in a container ap-
proved for flammable liquids.
OPERATE YOUR UNIT SAFELY
Ai_WARNING: Stop the engine before
opening the vacuum inlet door. The engine
must be stopped and the impeller blades no
longer turning to avoid serious injury from the
rotating blades.
Inspect unit before each use for worn,
loose, missing, or damaged parts. Do not
use unti_ unit is in proper working order.
Keep outside surfaces free of oil and fuel.
Never start or run engine inside a closed
room, building or other unventilated area.
Breathing exhaust fumes can kill.
To avoid static electricity discharge, do not
wear rubber gloves or any other insulated
gloves while operating unit.
Do not set unit on any surface except a
clean, hard area while engine is running.
Debris such as gravel, sand, dust, grass,
eta. could be picked up by the air intake and
thrown out through discharge opening,
damaging unit, property, or causing serious
injury to bystanders or operator.
Avoid dangerous environments. Do not use
in unventilated areas or where explosive
vapors or carbon monoxide build up could
be present.
Do not overreach or use from unstable sur-
faces such as ladders, trees, steep slopes,
rooftops, etc. Keep firm footing and balance
at all times.
Never place objects inside the blower
tubes; always direct the blowing debris
away from people, animals, glass, and solid
objects such as trees, automobiles, walls,
eta. The force of air can cause rocks, dirt, or
sticks to be thrown or to dcochet which can
hurt people or animals, break glass, or
cause other damage.
Never run unit without the proper equip-
ment attached. When using your unit as a
blower, always install blower tubes. When
using your unit as a vacuum, always install
vacuum tubes and vacuum bag assembly.
Make sure vacuum bag assembly is com-
pletaly zipped.
Check air intake opening, blower tubes,
vacuum tubes, and elbow tube frequent{y,
always with engine stopped and spark plug
disconnected. Keep vents and discharge
tubes free of debris which can accumulate
and restrict proper air flow.
Never place any object in the air intake open-
ing as this could restrict proper air flow and
cause damage to the unit.
Never use for spreading chemicals, fertiliz-
ers, or other substances which may contain
toxic matadais.
To avoid spreading fire, do not use near leaf
or brush fires, fireplaces, barbecue pits,
ashtrays, eta
Use only for jobs explained in this manual.
MAINTAIN YOUR UNIT PROPERLY
WARNING: Disconnect spark plug be-
fore performing maintenance except for carbu-
retor adjustments.
Have all maintenance other than the rec-
ommended procedures described in the in-
struction manual performed by an autho-
rized service dealer
Use only recommended Poulan PRO re-
placement parts; use of any other parts
may void your warranty and cause damage
to your unit
Empty fuel tank before storing the unit Use
up fuel left incarburetor by starting engine and
letting it run until it stops.
Do not use any accessory or attachment
other than those recommended by manufac-
turer for use with your unit.
Do not store the ueft or fuel in a closed area
where fuel vapors can reach sparks or an
open flame from hot water heaters, electric
motors or switches, furnaces, etc.
Store in a dry area out of reach of children.
WARNING: The engine exhaust from
this product contains chemicals known to the
State of California to cause cancer, birth de-
fects or other reproductive harm.
SPECIAL NOTICE: Exposure to vibra-
tions through prolonged use of gasoline pow-
ered hand tools could cause blood vessel or
nerve damage in the fingers, hands, and
joints of people prone to circulation disorders
or abnorma_ swelling Prolonged use incold
weather has been _inked to blood vesset dam-
age in otherwise healthy people. If symptams
occur such as numbness, pain, loss of
strength, change in skin color or texture, or
loss of feeling in the fingers, hands, or joints,
discontinue the use of this tool and seek
medical attention. An antivibration system
does not guarantee the avoidance of these
problems. Users who operate power tools on
a continual and regular basis must monitor
closely their physical condition and the condi-
tion of this took
SPECIAL NOTICE: This unit is equipped
with a temperature limiting muffler and spark
arresting screen which meets the require-
ments of California Codes 44-42 and 4443. All
U.S. forest land and the states of California,
Idaho, Maine, Minnesota, New Jersey, Ore-
gon, and Washington require by law that
many internal combustion engines be
equipped with a spark arresting screen. If you
operate in a locale where such regulations ex-
ist, you are legally responsible for maintaining
the operating condition of these parts. Failure
to do so is a violation of the law. Refer to the
MAINTENANCE section for information on
maintenance of the muffler and spark arrest-
ing screen.
-4-