Poulan PPG 6000 Portable Generator User Manual


 
19
CLEANING SPARK ARRESTER
See Figure 17.
Remove the eight 5 mm screws from the muffler
protector, then remove muffler protector.
Remove the 4 mm screw from the spark arrester and
remove the spark arrester.
Use a brush to remove carbon deposits from the
spark arrester screen.
Inspect the spark arrester for breaks or holes.
Replace if necessary.
Reinstall the spark arrester and muffler protector.
DRAINING CARBURETOR
See Figure 18.
Loosen the carburetor drain screw.
Allow gasoline to drain completely into suitable
container.
Retighten drain screw.
TRANSPORTING
Turn the engine switch and fuel valve OFF.
Make sure engine and exhaust system of unit is cool.
Keep the unit level to prevent fuel spillage.
Do not drop or strike the unit or place under heavy
objects.
Fig. 17
Fig. 18
STORAGE
When preparing the generator for storage, follow the guidelines below.
STORAGE TIME PRIOR TO STORING
Less than 1 month No special preparation is required.
1 to 2 months
Fill with fresh gasoline and add a gasoline conditioner*.
2 months to 1 year Fill with fresh gasoline and add a gasoline conditioner*.
Drain fuel from carburetor.
Clean fuel sediment cup.
1 year or more Drain fuel tank.
Drain fuel from the carburetor.
Clean fuel sediment cup.
Remove spark plug.
Put a tablespoon of engine oil into the spark plug cylinder. Turn the engine slowly with
the pull rope to distribute the oil.
Reinstall spark plug.
Change engine oil.
After removal from storage:
Fill with fresh gasoline.
*Use gasoline conditioners formulated to extend storage life. For recommendations, contact your nearest authorized
service center.
MAINTENANCE
STORAGE
DRAIN SCREW
SPARK ARRESTER