Porter-Cable 919.329150 Portable Generator User Manual


 
10 — ENG
D20498 Rev. 0 6/9/00
Place "L" bolt (B) through top and bottom brack-
ets and secure with wing nut (C).
Locate the solenoid on the left side of the unit.
Lawn & Garden batteries
can come in two terminal configurations. The
Positive (+) and Negative (-) terminals can be
oriented so that they are +/- or -/+. In the
unlikely event that the battery terminals are
unmarked, we recommend that you return the
battery to the retailer for exchange for a prop-
erly marked battery or let an authorized service
center install the battery for you. Failure to
connect the battery properly can possibly
cause bodily injury. In addition, extensive
engine electrical damage not be covered under
warranty can result.
To Prevent sparks connect
the red (positive) cable to the positive (+)
terminal before connecting the black negative
cable.
Remove the nut from the solenoid post closest to
the engine. Place one end of the positive (red)
battery cable onto the post. Reassemble nut and
tighten securely.
Slide protective cover over solenoid post.
Attach the other end of the positive (red) battery
cable to the positive (+) terminal on the battery.
Read owner’s manual. Do not attempt to operate equipment until you have read Owner’s
Manual for Safety, Assembly, Operation, Maintenance, Storage Instructions.
REMOVE GENERATOR FROM CARTON
Open carton from top.
Cut carton along dotted lines.
Remove all carton inserts.
Remove generator through opening in carton.
Using a 9/16 inch socket remove the two shipping
blocks from under the generator head. Unscrew
the bolts and remove the wood blocks. NOTE: It
is very important that these are removed before
starting your generator.
IMPORTANT: Before any attempt to start your genera-
tor be sure to check engine oil (See Adding Engine Oil
paragraph in the Operation section on page 14 of this
manual.)
TOOLS NEEDED FOR ASSEMBLY
1- Box Cutter or Knife
2 - 9/16 " Wrenches
2 - 1/2" Wrenches
1 - 1" thick x 1' square piece of wood
INSTALLATION OF BATTERY
Recommended Battery for Electric Start: 12V - 45 A H.
or 210 CCA (Cold Cranking Amps)
Purchase battery and battery hardware separately, not
included with unit.
Place battery in rack with terminals facing towards
generator head.
Place battery bracket (A) over battery as shown
(opposite battery terminals).
Solenoid
Solenoid
Protective
Cover