Polaris P1000i Portable Generator User Manual


 
70
TROUBLESHOOTING
Troubleshooting Symptoms
No Power at AC Receptacles
Engine Stops or Loses Power
POSSIBLE CAUSE SOLUTION
Output indicator is OFF, and
overload indicator is ON
Check the AC load; stop and restart the engine
Check the cooling air inlet; stop and restart the engine
AC circuit protector tripped Check the AC load and reset circuit protector
Faulty power tool or appli-
ance
Replace or repair the power tool or appliance; stop and
restart the engine
Faulty generator Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
POSSIBLE CAUSE SOLUTION
Out of fuel Refuel
Fouled, worn, incorrect, or
defective spark plug; incor-
rect spark plug gap or heat
range
Inspect, clean, and / or replace the spark plug, set the
spark plug gap to specification
Loose ignition connections Check all connections and tighten
Water present in fuel /
incorrect fuel
Drain the fuel system and refuel
Kinked or plugged fuel tank
vent line
Inspect and replace
SMART throttle control
malfunction
Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual
No / low oil in the engine Check / replace oil
Clogged air filter Clean or replace the air filter(s)
Overheated engine Clean cover screens
Mechanical failure Take the generator to an authorized POLARIS servicing
supplier or refer to the service manual