2 Pelco Manual C496M (12/90)
3.1 MODELS
HB6000 120 VAC thermostatically controlled
heater and blower. Heater provides
80 watts of heat and activates ON at
40°F (4.44°C) and OFF at 60°F
(15.56°C). Blower provides internal
air circulation (12 cfm at 4 watts) and
activates ON at 110°F (43.33°C) and
OFF at 80°F (26.67°C).
HB6000/220 Same as HB6000 except 230 VAC
operation. (Blower: 12 cfm at 4.5 watts)
HB6024 Same as HB6000 except 24 VAC
operation. (Blower: 19 cfm at 3 watts)
3.2 INPUT POWER REQUIREMENTS
Blower: HB6000 — 0.04 amp (4.5 vA)
HB6000/220 — 0.04 amp (4.5 vA)
HB6024 — 0.18 amp (4.5 vA)
Heater: HB6000 — 0.68 amp (80 vA)
HB6000/220 — 0.68 amp (80 vA)
HB6024 — 3.30 amp (80 vA)
3.3 RECOMMENDED CABLE SIZE
CAUTION: When using a single power
source for both the camera and accessories, the
camera power consumption must be taken into
consideration when determining the wire gauge.
The following cable sizes are the minimum recom-
mended for use with the combination of blower/heater/
camera.
Input Power
Model Voltage Consumption Cable Size Cable Distance
HB6000 120 VAC 90 watts 22 Awg 464.7 ft (141.64 m)
20 Awg 738.9 ft (225.22 m)
18 Awg 1,175.5 ft (358.29 m)
16 Awg 1,865.7 ft (568.66 m)
HB6000/220 230 VAC 90 watts 24 Awg 1,047.4 ft (319.25 m)
22 Awg 1,666.0 ft (507.80 m)
20 Awg 2,649.2 ft (807.48 m)
18 Awg 4,214.6 ft (1,284.61 m)
16 Awg 6,688.8 ft (2,038.75 m)
HB6024 24 VAC 90 watts 20 Awg 31.5 ft (9.60 m)
18 Awg 50.2 ft (15.30 m)
16 Awg 79.6 ft (24.26 m)
14 Awg 127.0 ft (38.71 m)