PART NUMBER PRESSURE RANGE ELECTRICAL PROOF/BURST ANALOG OUTPUT
PSI CONNECTION PRESSURE – PSI 0-10 VOLT AND 4-20mA
PSW32B 0 – 580 (0 – 40) DIN 43650 1450/2175 (100/150) No
PSW32B-A 0 – 580 (0 – 40) DIN 43651 1450/2175 (100/150) Yes
PSW32C 0 – 1450 (0 – 100) DIN 43650 2900/4350 (200/300) No
PSW32C-A 0 – 1450 (0 – 100) DIN 43651 2900/4350 (200/300) Yes
PSW32D 0 – 2320 (0 – 160) DIN 43650 4350/5800 (300/400) No
PSW32D-A 0 – 2320 (0 – 160) DIN 43651 4350/5800 (300/400) Yes
Numbers in parentheses indicate measurement in bar.
Notes: Mounting plates included.
For hydraulic applications with pressure spikes or surges install a pressure snubber.
All pressure switches are shipped with mounting screws, o-ring and mating electrical connector.
DIN 43650 without analog output DIN 43651 with analog output
1 +24V
3U
out Imax = 1A
20V
4 4 – 20mA
5 0 – 10V
PE
U
I
U
I
Micro-
Controller
SPRP
p
=
E
2
PROM
(SP,RP)
Load
1 +24V
3U
out Imax = 1A
2
0V
PE
I
Micro-
Controller
SPRP
p
=
E
2
PROM
(SP,RP)
Load
1.73 (44)
1.57 (40)
1.57 (40)
.47
(12)
.59 (15)
A
A
Ø.12 (3)
.94
(24)
1
/4 18 NPT
.22 (5.5)
.22 (5.5)
View on 'A'
M5
.35
(9)
.45 (11.5)
.79 (20)
Mounting Plates (Included)
1/4" NPT Pressure Port
304 Stainless Steel
All dimensions in inches (mm)
PART NUMBER IDENTIFICATION
ELECTRICAL PARAMETERS
Electrical connection DIN 43650 Table A without analog output
DIN 43651 (7 pin), with analog output
Power supply (polarity safe) 18 to 32V DC
Permissible residual ripple 10% (within 18 to 32V)
Current consumption <50 mA (plus load current)
SWITCHING OUTPUT
Switching mode Open collector PNP switched to supply
(suited for inductive load)
Output voltage Supply voltage minus 1.5V (approx)
Analog output O to l0V and 4 to 20mA
Contact rating I
max
= 1A (short-circuit proof)
Switching time < 5ms
Service life 100 million switching cycles
Switching logic Signal “on” with rising pressure, if SP* > RP**
Signal “on” with falling pressure, if SP < RP
* SP = Switching point **RP = Reset point
ELECTRONIC PRESSURE SWITCH FOR HYDRAULIC APPLICATIONS