Northern Industrial Tools 15000 PPG Portable Generator User Manual


 
4
GENERATOR FEATURES
Reference 1 - Air Cleaner. Refer to your Kohler
engine manual for air cleaner care.
Reference 2 - Circuit Breakers. This portable
single phase generator has 1 - 60 amp (A) thermal
magnetic 2 pole breaker, 1 - 30 amp (A) thermal
magnetic 2 pole breaker 1 - 30 amp (A) push to reset
circuit breaker, and 2 - 20 amp (A) push to reset circuit
breakers. Circuit breakers protect against electrical
overloads.
Reference 3 - 120/240V Receptacle. This
receptacle is a 120/240V 60A NEMA 14-60R
receptacle. This receptacle accepts a NEMA plug
number 14-60P, which is supplied with the generator.
Use this receptacle if installing a transfer switch.
Compatible with Gentran transfer switch, item
#164117.
Reference 4 - 120/240V Twistlock Receptacle.
This twistlock is a 120/240V 30A NEMA L14-30R
receptacle. This receptacle accepts a NEMA plug
number L14-30P, which is supplied with the generator.
Reference 5 - 120V Twistlock Receptacle. This
twistlock is a 120V 30A NEMA L5-30R receptacle.
This receptacle accepts a NEMA plug number L5-30P,
which is supplied with the generator.
Reference 6 - 120V Receptacle. The generator
has a control panel with two duplex (two receptacles in
a common housing) receptacles. Each duplex is a 120
volt (V) 20 amp (A) straight blade receptacle, National
Electrical Manufacturer’s Association (NEMA) number
5-20R. This receptacle accepts NEMA plug numbers
5-15P and 5-20P. Each duplex is capable of drawing
20A at 120V.
ALWAYS use grounded male plugs. The neutral
line of the generator is mechanically grounded to the
frame. Matching NEMA male plugs must always be
used.
WARNING Contact a licensed electrician
to wire electrical plugs and/or cordsets. Improper
wiring could result in a fire or electrical shock.
Reference 7 - Oil Drain Valve. Refer to your
Kohler engine manual for oil change
recommendations.
Reference 8 - Vibration Isolation Mounts. The
engine and generator head are mounted on rubber
cylinders that absorb most of the engine vibration.
This feature eliminates the tendency of the machine to
“walk” which is common in engine powered equipment.
Reference 9 - Starting/Stopping Instructions.
Reference 10 - Wheel Kit. Heavy duty wheel kit
(Item # 165919).
Reference 11 - 10.0 Gallon Gas Tank. Large
tank allows for extended run capabilities. Alw ays
allow room for gasoline expansion by not filling the gas
tank completely full.
Reference 12 - Engine Key. The engine key
switch is located on the front of the engine. Always
locate this switch and be familiar with its location
before operating the generator.
Reference 13 - Choke Lever. Used during cold
starts. Refer to the starting/stopping instructions and
the Kohler Command 25 engine manual for usage.
Reference 14 - Muffler and Spark Arrestor.
Reference 15 - Oil Filter. Kohler oil filter number
12-050-01 or equivalent.
Reference 16 - Battery Box and Battery.
Battery is shipped without electrolyte. Fill each battery
cell to the fill line with locally purchased electrolyte
(sulfuric acid and water).
WARNING Sulfuric acid is a corrosive
poison. Avoid contact with skin, eyes or clothing.
Reference 17 - Gas Line Valve. The generator
tank has an ON-OFF valve mounted underneath the
tank. Always keep this valve closed when the
generator is not in use.
Reference 18 - Generator Head. The electricity
producing part of the generator.
Reference 19 - Gas Drain Valve. The generator
is equipped with a unique feature. A gas drain valve is
installed to drain gasoline from the tank without
disconnecting the gas line feeding the engine. This
valve is intended to be used to drain gas prior to
extended periods of non use. It is recommended that
if the period of non use is longer than 30 days, the gas
should be drained, and the engine run until all the gas
is evacuated from the carburetor. ALWAYS make
sure this valve is closed prior to filling the gas tank.
Reference 20 - Gas Cap with Gauge. The gas
cap is extra large, creating a large hole for refilling and
a comfortable grip. You can always monitor the fuel
level without removing the cap by using the fuel level
indicator built into the gas cap.
Low Oil Shutdown. The Kohler engine is
protected against damage resulting from low oil level.
As the oil falls below the safe level, the engine
automatically shuts off (the engine stop switch remains
in the on position). The engine will not start until the
oil is refilled to above the safe level.
INTRODUCTION
Before starting your generator, thoroughly study
the instructions and cautions in this manual to assure
you are fully acquainted with the operation of all
components of this generator. Proper preparation,
operation and maintenance will result in operator
safety, best performance and long life of the generator.
For detailed engine operation and maintenance always
refer to the Kohler engine owner’s manual furnished
with the generator.
North Star is constantly improving its products.
The specifications outlined herein are subject to
change without prior notice or obligation. The
purchaser and/or user assumes liability of any
modification and/or alterations on this equipment from
original design and manufacture.
Before using, the user shall determine the
suitability of this product for its intended use and
assumes liability therein.