North Star M165912I.3 Portable Generator User Manual


 
Machine Component Identification 165912I.3 (cont’d)
9
REFERENCE GUIDE
Reference 1 Circuit Breaker
This portable single phase generator has 1, 20
amp (A) push to reset circuit breaker to protect
against electrical overloads.
Reference 2 (2) 120V 20A
Duplex Receptacles
The generator has a control panel with two 120V
duplex (two receptacles in a common housing)
receptacles. The duplex is a 120 volt (V) 20 amp
(A) straight blade receptacle, National Electrical
Manufacturer’s Association (NEMA) number 5-
20R. This receptacle accepts NEMA plug
numbers 5-15P and 5-20P. Each receptacle on
the duplex is capable of drawing 20A.
Reference 3 Generator Head
The electricity producing part of the generator.
Reference 4 Oil Drain Plug
Refer to your Honda engine manual for oil
change recommendations.
Reference 5 Vibration
Isolation Mount
The engine and generator mounted on rubber
cylinders that absorb most of the engine
vibration. This feature eliminates the tendency
of the machine to “walk” which is common in
engine powered equipment.
Reference 6 Muffler
Honda’s standard muffler with an installed spark
arrestor.
Reference 7 Choke Lever
Used during cold starts. Refer to the Honda
engine manual for usage.
Reference 8 Ignition Switch
Lever
The red engine stop lever is located on the
engine. Always locate this lever and be familiar
with its location before operating the generator.
Reference 9 Recoil
Grasp firmly when pull starting the engine.
Reference 10 Gas Tank
Always allow room for gasoline expansion by
not filling the gas tank completely full.
Reference 11 Air Cleaner
Refer to your Honda engine manual for air
cleaner care.