Nilfisk-Advance America 5 Pressure Washer User Manual


 
8
english
1)
Options / model variants
POSEIDON 5
CHEM
MAX
CHEM
MAX
ca.
5%
3%
1%
0%
4.3 Pressure regulation
(Tornado Lance)
1. Turn the twist grip on the
spray unit:
High pressure =
clockwise (+)
Low pressure =
anticlockwise (–)
4.4 Pressure regulation
with the FlexoPowerJet
nozzle
1. Twist cap of the FlexoPowerJet
nozzle:
High pressure = MAX.
Low pressure = MIN.(CHEM)
4.5 Pressure regulation on
the machine
1. Set pressure and water vol-
ume by twisting the pres-
sure/volume regulation knob
on the machine.
4.6 Using cleaning agents
Cleaning agent can be drawn
in via the injector installed as
standard only in low-pressure
mode:
1. Dilute cleaning agent ac-
cording to the manufacturer‘s
instructions. Capacity see
chapter 9.4 Technical Data.
2. Tornado lance
1)
:
Set pressure regulation on
spray lance to low pressure
(–), or
FlexoPowerJet nozzle
1)
:
Turn cap of the FlexoPower-
Jet nozzle towards „CHEM“
up to the stop.
3. The intaken volume of clean-
ing agent can be regulated by
turning the metering valve.
4. Main switch
Turn the switch to position
I „.
5. Operate the spray gun.
CAUTION!
Never allow cleaning agent
to dry on the surface to be
cleaned. The surface may be
damaged.