National Instruments 5441 Portable Generator User Manual


 
© National Instruments Corporation 31 NI 5441 Specifications
Specification Value Comments
FIR Filter Types
Filter Type Parameter Minimum Maximum
Custom Coefficients
are provided
by the user.
Flat Passband 0.1
0.43 Lowpass Filter
that minimizes
ripple to:
IQ Rate ×
Passband.
Gaussian BT 0.1 0.9
Raised Cosine Alpha 0.1 0.9
Root Raised
Cosine
Alpha 0.1 0.9
CIC (Cascaded Integrator-Comb) Filter
Size 6 Stages The CIC Filter
does the
majority of the
interpolation
in the OSP.
Interpolation
Range
6 Interpolation256 (integers)
NCO (Numerically Controlled Oscillator)
Frequency
Range
1 mHz to (0.43 × Sample Rate)
Frequency
Resolution
Sample Rate / 2
48
Example:
355 nHz with a
Sample Rate
of 100 MS/s
I and Q Phase
Resolution
0.0055º
Phase
Quantization
16 bits Look-Up
Table Address
Width
Tuning Speed 1 ms