Multiquip GAC6HZ Portable Generator User Manual


 
GAC-6HZ 60 HZ GENERATOR • OPERATION AND PARTS MANUAL — REV. #1 (03/31/10) — PAGE 25
MAINTENANCE
Use Table 5 as a general maintenance guideline when
servicing your engine. For more detail engine maintenance
information, refer to the engine owner's manual supplied
with your engine.
Table 5. Engine Maintenance Schedule
DESCRIPTION
(3)
OPERATION BEFORE
FIRST
MONTH OR
10 HRS.
EVERY 3
MONTHS
OR 25 HRS.
EVERY 6
MONTHS
OR 50 HRS.
EVERY
YEAR OR
100 HRS.
EVERY
2 YEARS OR
200 HRS.
Engine Oil
CHECK X
CHANGE
Air Cleaner
CHECK
X X
CHANGE X (1)
All Nuts & Bolts
RETIGHTEN IF
NECESSARY
X
Spark Plug
CHANGE X
REPLACE
X
Cooling Fins CHECK X
Spark Arrester CLEAN X
Fuel Tank CLEAN X
Fuel Filter CHECK X
Idle Speed CHECK-ADJUST X (2)
Valve Clearance CHECK-ADJUST X (2)
Fuel lines CHECK Every 2 years, replace if necessary (2)
(1) Service more frequently when used in DUSTY areas.
(2) These items should be serviced by your service dealer, unless you have the proper tools and are mechanically
proficient. Refer to the HONDA Shop Manual for service procedures.
(3) For commercial use, log hours of operation to determine proper maintenance intervals.