Milwaukee 4960-24 Portable Generator User Manual


 
6 www.milwaukeetool.com
A - Circuit Breakers (AC) — The receptacles are provided
with circuit breakers to protect the generator against
electrical overload.
B - Idle Control Switch — Use this switch to turn the idle
control feature on and off.
C - Engine Switch — Set this switch to “On” before using
recoil starter. Set switch to “Off” to stop engine.
D - Double Pole Circuit Breaker (AC) — A double pole
circuit breaker is provided to protect the 120/240V, 20A
receptacle against electrical overload.
E - GFCI Main Circuit Breaker — A GFCI circuit breaker is
provided to protect against electrical ground fault and
protect the generator against electrical overload.
F - 120/240 Volt AC, 30 Amp Locking Receptacle — May
be used to supply electrical power for the operation of
120 and/or 240 Volt AC, 30 Amp, single phase, 60 Hz
electrical, lighting, appliance, tool and motor loads.
G - 120 Volt AC, 30 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 30 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
H - 120 Volt AC, 20 Amp Locking Receptacle — May be
used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical
lighting, appliance, tool and motor loads.
J - 120 Volt AC, 20 Amp, Duplex Receptacles — May
be used to supply electrical power for the operation of
120 Volt AC, 20 Amp, single phase, 60 Hz electrical,
lighting, appliance, tool, and motor loads.
K - Grounding Fastener — Consult your local agency having
jurisdiction for grounding requirements in your area.
L - Spark Arrester Muffler — Exhaust muffler lowers engine
noise and is equipped with a spark arrester screen.
M - Air Cleaner — Protects engine by filtering dust and
debris out of intake air.
N - Oil Fill Cap/Dipstick — Check and add engine oil here.
P - Recoil Starter — Used to start the engine.
R - Engine Identification — Provides model, type and code
of engine. Please have these readily available if calling for
assistance.
S - Fuel Valve — Used to turn fuel supply on and off to
engine.
T - Choke Lever — Used when starting a cold engine.
U - Fuel Tank — Capacity of 7.5 U.S. gallons (28.4 L).
V - Center Point Lift — The lift point in the center of the
unit makes lifting the machine for transportation and/or
relocation easy.
Items Not Shown:
Data Tag — Provides model, revision, and serial number of
generator. Please have these readily available when calling
for assistance.
Oil Drain Plug — Drain engine oil here.
Read this Operator’s Manual and safety rules before operating your generator.
Compare the illustrations with your generator, to familiarize yourself with the locations of various controls and
adjustments. Save this manual for future reference.
Features and Controls
H
A
G
F
E
C
B
S
M
L
V
J
K
P
T
R
N
D
U