Miller Electric 6000 Portable Generator User Manual


 
OM-499 Page 26
Return To Table Of Contents
8-3. Overload Protection (Honda-Powered Units)
1 Ignition Circuit Breaker
(Electric-Start Models Only)
The circuit breaker protects the en-
gine battery charging circuit. A
short circuit or a battery connected
in reverse polarity will trip the circuit
breaker.
Press button to reset breaker.
. If a switch or breaker opens, it
usually indicates a more seri-
ous problem exists. Contact a
Factory Authorized Service
Agent.
1
Ref. 802 094-A
3
1
2
8-4. Adjusting Engine Speed (Kohler-Powered Units)
802 511-A / Kohler Dwg.
After tuning engine, check engine
speeds. See table for proper no
load speeds. If necessary, adjust
speeds as follows:
Start engine and run until warm.
Weld/Power Speed
Adjustment
1 Throttle Control Lever
2 Adjustment Screw
Move lever to Run (far right) posi-
tion. To increase speed, turn screw
out (counterclockwise) while lightly
pushing lever to the right. To de-
crease speed, turn screw in (clock-
wise).
Idle Speed Adjustment
3 Adjustment Screw
Move lever to idle (far left) position.
To increase idle speed, turn screw
in (clockwise). To decrease idle
speed, turn screw out (counter-
clockwise).
Y Stop engine. Close fuel
valve.
Tools Needed:
2000 ± 150 rpm
3720 ± 50 rpm (60 Hz)
3250 ± 50 rpm (50 Hz)
Top View
Top View