Makita G571O R Portable Generator User Manual


 
5.
AUTO
IDLE
(GSlOR, G3511 R, G571OR,
6571
1
R)
AUTO IDLE automatically reduces engine speed when load is
OFF,
and automat-
ically increases engine speed to rated r.p.m. when load is
ON.
AUTO IDLE provides fuel economy and low noise operation at no-load running.
(1)
HOW TO USE AUTO IDLE
I
Start the engine with AUTO IDLE
SWITCH
off.
NOTE
:
Warm up the engine without a load for a
few minutes.
m
Turn AUTO IDLE SWITCH on.
f
FULL
POV
(2) CHECKING THE OPERATION
I
Overloadede
?
When AUTO IDLE does not operate normally, please check following
:
Please make
it
sure that the generator is not overload.
NOTE
:
Most induction loads such as electric motors require three to five times more
wattage than their ratings during starting.
This starting wattage should not exceed the rated output of the generator for
proper operation of AUTO IDLE.
I
Turn AUTO IDLE SWITCH
off
when the AUTO
IDLE
does not work normally
under the rated output.
NOTE
:
The AUTO IDLE may not operate when the applied load is under 40W. In such
cases turn the AUTO IDLE SWITCH
off.
(3)
STOPPING THE ENGINE
I
Turn
off
the switch of load.
I
Switch
off
generator’s AC breaker.
I
Disconnect tool or appliance.
I
Turn the AUTO
IDLE
SWITCH
off.
Push STOP SWITCH to stop.
NOTE
:
Allow the engine about
3
minutes to cool down at no-load before stopping.
-