(3)
DC APPLICATION
DC output capacity of generator is 12V-8.3A (1OOW).
Connect positive (red) terminal on gen-
erator to position
(+)
terminal on battery.
Connect negative (black) terminal on
generator to negative
(-)
terminal on
battery.
Both AC and DC output can be used at
the same time if the total output is within
rated output
of
the generator.
SAFETY PRECAUTIONS WHILE CHARGING
An explosive hydrogen gas is discharged through vent holes in the battery
during the charging process.
Do
not allow spark or open flame around the
generator or battery during the charging process.
Electrolyte fluid can burn eyes and clothing. Be extremely careful to avoid
contact.
If
injured, wash the affected area immediately with large quantities of
water and consult a doctor for treatment.
When charging a large capacity battery or totally discharged battery, exces-
sive current may force the DC fuse to blow out.
In
such cases, use a battery
charger to charge a large battery with AC output.
Battery defects may cause the DC fuse to blow. Check the battery before
replacing the fuse.
(4)
FUSE REPLACEMENT
(a)
If
a fuse burns out, check for the cause of trouble, and make the necessary
(b) Be sure to use the correct fuse. An incorrect fuse may cause damage to the
(c) The fuse rating for DC output is 10A.
repaires before installing the new fuse.
generator.
-
16
-