Lincoln Electric 300 D Portable Generator User Manual


 
D-4
MAINTENANCE
D-4
CLASSIC 300D
I
EVERY 400 HOURS OR 12 MONTHS
EVERY 200 HOURS OR 6 MONTHS
EVERY 100 HOURS OR 3 MONTHS
FIRST SERVICE-(20 / 50 HOURS)
EVERY DAY OR EVERY 8 HOURS
Perkins #140517000
If necessary use shorter periods.
These preventive maintenance periods apply to average conditions of operation.
Perkins #26560017
TYPE OR QUANTITY
Above operations to be carried out by trained personnel with reference to the workshop manual where necessary.
9.5qrts., 9.0L
(3) Fill slowly! Ensure correct quantity is used.
8.7qrts, 8.2L (including filter)
(2) Consult Engine Operators Manual for additional maintenance schedule information.
(1) Consult Engine Operators Manual for oil recommendations.
Notes:
Alternator drive belt
Alternator drive belt wear
R
Tension of alternator drive belt
Fuel filter canister
I
Drain water separator & fuel strainer
Engine oil (NOTE 1 & 3)
R
Engine oil level (NOTE 1)
Coolant (NOTE 3)
MAINTENANCE ITEM
Concentration of antifreeze
C
I
R
Coolant level
R
C
R
R
I
R
ENGINE SERVICE
I
EVERY 600 HOURS OR 18 MONTHS
S25557
Contact Perkins
Intake .008", exhaust .008"
Donaldson #P181050, Nelson #70206N
R = ReplaceC = Clean
Battery
Leaks or engine damage
I
Injector performance
All nuts and bolts for tightness
I = Inspect
Electrical systems
I
I
Valve clearances
I
Tighten cylinder head
I
I
Check and adjust idle speed
I
Air filter element
Air filter (earlier check may be req’d.)
R
I
CC
Engine oil filter
ENGINE SERVICE (NOTE 2)
50/50 Water/Ethylene Glycol
Perkins #080109080
FOR CODES 10911 AND ABOVE