Lincoln Electric 300 D Portable Generator User Manual


 
B-3
OPERATION
B-3
CLASSIC 300D
Auxiliary Power
The AC auxiliary power, supplied as a standard, has a
rating of 3.0 kVA of 115/230 VAC (60 hertz).
With the 3.0 kVA, 115/230 VAC auxiliary power, one
115V duplex and one 230V duplex, grounding type
receptacle are provided. The circuit is protected with
circuit breakers.
The rating of 3.0 kVA permits a maximum continuous
current of 13 amps to be drawn from the 230 volt
duplex receptacle. Or a total of 26 amps can be drawn
from the 115 volt duplex receptacle. The 115 volt
duplex receptacle has a configuration which permits
20 amps to be drawn from either half. The total com-
bined load of all receptacles is not to exceed 3.0 kVA.
An optional power plug kit is available. When this kit is
specified, the customer is supplied with a plug for
each receptacle.