Operating Instructions HD 10/25 S VEX English
12
Technical Specifications
HD 10/25 S VEX
Mains connection
Voltage V 380 220
Type of current Hz 3~50 3~60
Connected load kW 7.7 7.5
Supply fuse (delayed-action, char. C) A 16 25
Max. tolerable mains impedance Ω (0.145 + j0.090)
Extension cable 10 m mm
2
2.5 2.5
Extension cable 30 m mm
2
4–
Water connection
Supply temperature max. °C 60
Supply volume min. l/h (l/min) 1200 (20)
Supply hose – minimum length m 7.5
Supply hose – minimum diameter inches 3/4
Suction height from an open container 20 °C m 0.5
Supply pressure max. MPa (bar) 1 (10)
Performance data
Operating pressure MPa (bar) 3–19 (30–190)
Max. operating overpressure (safety valve) MPa (bar) 20.9 (209)
Flow rate
l/h (l/min)
500–1038 (8.3–17.3)
Detergent intake
l/h (l/min)
0–80 (0–1.3)
Recoil force of the handgun N 62
Sound emission
Sound pressure level
(EN 60704-1)
dB (A)
72
Guaranteed sound pressure level
(2000/14/EC)
dB (A) 87
Vibrations of unit / total of vibration (ISO 5349)
Handheld gun m/s
2
2.2
Spray lance m/s
2
2.0
Dimensions
Length mm 560
Width mm 500
Height mm 1090
Weight without accessories kg 62
Reservoir capacity, detergent l 6
Oil quantity, pump l 1.2
Oil type, pump SAE 90