John Deere HR-G1100 Portable Generator User Manual


 
Operating the Generator
30 Operator’s Manual
OPERATION
SPARK ARRESTER:
In a dry or wooded area, it is recommended to use the product with a
spark arrester. Some areas require the use of a spark arrester. Please
check your local laws and regulations before operating your product.
The spark arrester must be cleaned regularly to keep it functioning as
designed.
A clogged spark arrester :
Prevents the flow of exhaust gas
Reduces engine output
Increases fuel consumption
Makes starting difficult
CAUTION: IF THE ENGINE HAS BEEN RUNNING, THE
MUF FL ER AND TH E SPAR K AR RE ST ER
WILL BE VERY HOT. ALLOW THE MUFFLER TO COOL
BEFORE CLEANING THE SPARK ARRESTER.
How to remove the spark arrester (Fig. 13):
1. Remove the flange bolts from the muffler cover and remove the
muffler cover.
2. Remove the special screw from the spark arrester and remove the
spark arrester from the muffler.
Clean the spark arrester screen (Fig. 14):
1. Use a brush to remove carbon deposits from the spark arrester screen.
Be careful to avoid damaging the screen.
2. The spark arrester must be free of breaks and holes. Replace the
spark arrester if it is damaged.
3. Install the spark arrester, and muffler protector in the reverse order
of disassembly.
(Fig. 14)
SPARK ARRESTER SCREEN
SPARK
ARRESTER
SCREEN
SCREW
MUFFLER
(Fig. 13)