Storage
Operator’s Manual 27
WINTERIZING
WARNING: RISK OF UNIT BURSTING! DO NOT STORE OR OPERATE
UNIT IN A FREEZING ENVIRONMENT!
For storage and transportation purposes in subfreezing ambient temperatures, it
will be necessary to winterize this unit. This unit must be protected to the lowest
incurred temperature for the following reasons:
1. If any part of the pumping system becomes frozen; excessive pressure may
build up in the unit which could cause the unit to burst resulting in possible
serious injury to the operator or bystanders.
2. The pumping system in this unit may be permanently damaged if frozen.
FREEZE DAMAGE IS NOT COVERED BY WARRANTY.
If you must store your unit in an area where the temperature may fall below 32°F,
you can protect your unit by following the procedure outlined below.
1. Gather the following items:
a. Two 5 gallon containers.
b. One gallon of antifreeze. (John Deere recommends an environmentally
safe antifreeze.)
c. Water supply.
d. Three foot hose, 1/2-3/4 I.D. with a 3/4 inch male garden hose fitting.
2. Procedure:
a. To start winterizing, unit must be run and primed according to the "Start-
up Procedures" listed on page 14.
b. After running and priming, shut off the unit and water supply.
c. Relieve system pressure by pointing the trigger gun in a safe direction
and squeezing the trigger until water flow ceases to exit the nozzle.
d. Lock the trigger gun in an OFF position and remove the nozzle.
e. Remove the water supply hose from the unit and attach the 3 foot hose
securely to the inlet connection.
f. Shut off the detergent injector if applicable.
g. Fill one 5 gallon bucket with water.
h. Holding the 3 foot hose in an upright position, completely fill the hose
with water. Then plug the hose outlet with your thumb or finger. Place
the plugged end into the 5 gallon bucket of water.
i. Turn the unit on. Trigger the gun several times until all the air is worked
out of the system (unit is primed).
NOTE: Proper winterizing is based on the recommended manufacturer's
instructions listed on the "Protection Chart" shown on the back label of
most antifreeze containers.
j. With the trigger gun held open, siphon enough water out of the 5 gallon
bucket until there is just enough water left to mix with the antifreeze.
k. Point the wand into the empty container and start the unit.
l. Trigger the gun until the antifreeze begins to exit the wand. Release
the trigger for 3 seconds, then trigger the gun for 3 seconds. Continue
cycling the gun several times until all the antifreeze mixture is siphoned
from the container.
m. Detach the 3 foot hose from the unit and drain any excess antifreeze
back into the 5 gallon container.
n. Disconnect the hose/gun/wand assembly from the unit and drain any
excess antifreeze back into the 5 gallon container.
o. Store the hose, gun and wand with the unit in a safe area.
p. Store antifreeze solution for next use or dispose of according to state
EPA laws.
32˚F 0˚C