Jacuzzi N885 Hot Tub User Manual


 
Cetra®536 Whirlpool Bath
Model: N875, N880
Cetra® 536 Bath
Model: N885
Installation Notes
Refer to installation instructions included with fi xture before beginning installation.
Please confi rm product availability and specifi cations before commencing with any
installation work.
PRODUCT SPECIFICATIONS AND AVAILABILITY ARE SUBJECT TO CHANGE
WITHOUT NOTICE.
Electrical Components and Electrical Specifi cations do not apply to non-jetted baths.
Ordering Information
Product Code:
N875 Cetra® 536 Whirlpool Bath
Left Hand
N880 Cetra® 536 Whirlpool Bath
Right Hand
N885 Cetra® 536 Bath
• Right and Left Hand Drain Location
• Accessories / Hardware:
Trip-Lever Drain Kit: #X559
Rotary Drain Kit, 26” Cable: #8730
Trim Kit: 1 X TheraPro™ Jet Rings #D095
Trim Kit: 2 X AccuPro™ Jet Rings #J869
• Trim Kit Finishes Available:
(827) – Chrome
(898) – Brushed Chrome
(815) – Satin Nickel
(829) – Bright Brass
(805) – Platinum
(826) – Brushed Nickel
(849) – Oil Rubbed Bronze
Technical Specifi cations
Dimensions
60” L x 36” W x 21-1/4” H
(1524 mm) L x (914 mm) W x (540 mm) H
Drain/Overfl ow
A: 18-1/2” (470 mm) B: 9” (229 mm)
Cutout
58” x 34-1/4”
Total Weight
N875, N880: 742 lb (337 kg) / 50 lb/sq. ft. (242 kg/m
2
)
N885: 707 lb (321 kg) / 47 lb/sq. ft. (230 kg/m
2
)
Operating Gallonage
48 U.S. Gal. (181 Liters)
Max. 55 U.S. Gal. (208 Liters)
Product Weight
N875, N880: 92 lb (42 kg)
N885: 57 lb (26 kg)
Skirt Mounting
Optional U-Frame
Electrical Specifi cations Models N875, N880 only
Requires a dedicated GFCI protected separate circuit.
Motor/Pump: 120 VAC, 15 AMP, 60 Hz.
RapidHeat™: 120 VAC, 15 AMP, 60 Hz.
Heater (Optional) Models N875, N880 only
Requires a dedicated GFCI protected separate circuit.
RapidHeat™: P/N S750000
9"
60"
36"
18"
12" x 4"*
Motor
12" H x 18" L
Service Access
Opt. Service Access
2"
5-3/4"
© Jacuzzi Whirlpool Bath • 14880 Monte Vista Avenue • Chino • CA • 91710 • www.jacuzzi.com
END VIEW
H
W
SIDE VIEW
L
2"
#FR28 07/07
DRAIN/OVERFLOW
A
B
Product Shown: Cetra® 536 Whirlpool Bath Left Hand Model: N875
* Measurements inside unit represent cutout in fl oor to allow for drain/overfl ow.
Minimum Service Access dimensions given.