Jacuzzi J - 280 Swimming Pool Vacuum User Manual


 
J-200
14.6 Panel Flashes FL1 or FL2 (Spas Without Circulation Pump
Option)
A ashing “FL1” display means the pressure switch is
not closed when the jets pump 1 is activated. Proper
water ow is inhibited or the pressure switch has
malfunctioned. A ashing “FL2” display means the
pressure switch is malfunctioning closed. In either case,
the heater is deactivated. To correct condition, perform to the following:
Verify water level is one inch below lowest pillow. Add water if 1.
necessary.
Check for clogged or dirty lter cartridge (Sec. 12.1, page 2. 32).
Purge “air lock” from jets pump 1 by loosening the upper pump head 3.
drain screw (Figure A, page 17) for a few seconds to release trapped
air, then retighten drain screw. FINGER TIGHT ONLY!
If problem persists, contact your authorized Jacuzzi dealer.4.
14.7 Panel Flashes FL1 or FL2 (Spas With Circulation Pump
Option)
A ashing “FL1” display means the ow switch is
malfunctioning open, the lter cartridge is excessively
dirty or an “air lock” condition has occurred at the
circulation pump intake. A ashing “FL2” display means
the ow switch is malfunctioning closed. In either case,
the spa heater will deactivate and jets pump #1 may also deactivate. To
correct condition perform the following:
Verify water level is 1" below lowest pillow. Add water if necessary.1.
Check for clogged or dirty lter cartridge (Sec. 12.1, page 2. 32).
Purge “air lock” from circulation pump intake by removing lter 3.
cartridge. Hold your garden hose over the lter cartridge wall tting
while using a rag as a seal around hose end. Ask a helper to turn
on water for 30 seconds, then turn off. Reinstall lter cartridge and
check spa (Sec. 12.1, page 32).
If the circulation pump is not running, turn power off at the main 4.
breaker, then turn power back on. This will reset the circulation pump
priming cycle. Once the pump is primed, the error should clear.
If problem persists, contact your authorized Jacuzzi dealer. 5.
41