J-300
 
This wiring diagram is used for all Export 230 VAC 50 Hz spa models.
Optional Stereo And Power Supply
Power Supply
OZONATOR
(optional)
O
3
GRN
TB1
230 VAC 3-Wire Connection (50Hz, 1-Phase Service)
USE COPPER CONDUCTORS ONLY. WIRE SIZE MUST BE
APPROPRIATE PER NEC AND/OR LOCAL CODES
BLU
BLU
J6
BRN
J5
BRN
BRN
BLU
BLK
BLU
BLU
BRN
BLU
BRN
BLU BLU
BRN BRN
BRN
2
1
FLOW SWITCH
HI - LIMIT / FREEZE SENSOR
TEMPERATURE SENSOR
J1
J2
J3
F1
20A, 250V
SC-20
PUMP 1
PUMP 2
TRANSFORMER
240 VAC
F1
JP1
4
2
3
1
6 5
8 7
7 6 2 4
HI
HI
LO
C
Control Panel
CIRC.
PUMP
J20
K1
K2
K3
K4
K5
K6 K7 K8
J21
J11
J12
J13
J14
J15
J16
J17
J18
J19
J7 J8
J9
J10
Logic Jumper Settings (Factory Defaults Shown)
JP1 1-2 ON = 20A Logic
JP1 1-2 OFF = 30A Logic
JP1 3-4 ON = 2 Pump Operation
JP1 3-4 OFF = 1 Pump Operation
JP1 5-6 ON = 40A Logic (Remove JP1 1-2 Jumper)
JP1 5-6 OFF = Leave Off for 20A or 30A Logic
JP1 7-8 ON = Celsius Temperature Display
JP1 7-8 OFF = Fahrenheit Temperature Display
Heater
2.7 kW @
230 VAC
J4
X
W
12VAC Output to
Waterfall Light/
Footwell Light
Controller
X W
12 VAC From
Transformer
Blue wires 12 VAC
constant voltage
(connects to the
yellow wires on
the transformer)
Light
DCU
Waterfall and Footwell
lights can connect to any
plug on the DCU (P/N
6560-134)
Yellow Connector
Control Panel
A
A
6560-134