Ingersoll-Rand 651747-X-B Patio Heater User Manual


 
PAGE 4 OF 4 651747ĆXĆB
TROUBLE SHOOTING
Fluid heater will not produce heat.
No current to the heater unit.
Check the main power switch.
Check the power supply fuse, etc.
Damaged thermostat.
Replace the thermostat.
The heat limiter is burned out.
Replace the heat limiter.
The heat element is burned out.
Replace the heater cartridge element.
The temperature of the material is too low.
The voltage to the heater is too low.
Correct the wiring.
The thermostat is damaged.
Replace the thermostat.
The thermostat setting is wrong.
Adjust the thermostat.
Material buildĆup inside the heater.
Clean the fluid heater and material lines.
The material flow is too fast.
Reduce the material flow.
The temperature of the material is too high.
The thermostat is damaged.
Replace the thermostat.
Wrong setting on the thermostat.
Reset the thermostat.
The heater takes too long to heat the material.
The voltage is too low.
Correct the wiring.
Material buildĆup inside the heater.
Clean the fluid heater and material lines.
Inadequate material flow.
Material buildĆup inside the heater.
Clean the fluid heater and material lines.
TYPICAL INSTALLATION
TYPICALSINGLEHEATER
FIGURE 4
TYPICALDUAL HEATER
``A"
``A"
``B" ``B"
``C"
``C"
``A" = Material Outlet
``B" = MaterialInlet
``C" = Power In
ACCESSORIES
66258 Mounting Bracket Assembly
FIGURE 5
11/16" (17.5 mm)
1Ć11/16"
(42.9 mm)
6" (152.4 mm)
2Ć1/4"
(57.2 mm)
3/8" dia. (9.5 mm) 6x
PN 97999Ć557