Husqvarna 220 AC Lawn Mower User Manual


 
English - 57
6. MENU FUNCTIONS
Advanced (3-4)
Check loop (3-4-1)
This function allows you to check the mower’s
signal reception from the boundary wire, and to
determine exactly where in the lawn the
boundary wire is routed.
The sensor used for this function sits concealed
directly under the catch button for the cutting
height adjustment cover. The sensor detects the
position of Automower in relation to the loop.
Inside, Outside or No loop signal are shown on
the display. If the mower is inside the loop, Inside
is shown, etc. If the mower is set with sound on,
a constant beep is also heard when the mower is
outside and a pulsating beep when it cannot
detect a signal. If the mower is inside the loop no
beep is heard.
To:
Check the signal reception: Move the cursor to
Check loop and press YES.
Find wire: Move Automower over the outer edge
of the working area and select Check loop.
Repeat until you find the boundary between
Inside and Outside. You now know where the
wire is.
Drive past wire (3-4-2)
The front of Automower always passes the
boundary wire by a specific distance before the
mower turns. The default distance is 27 cm, but
this can be changed if required. The minimum
value is 15 cm and the maximum value is 50 cm.
To adjust the distance: Move the cursor to Drive
past wire and press YES. Now specify the
number of centimetres you want Automower to
pass the boundary wire.
3-4
3-4-1
Check loop
Drive past wire
Exit angles
Follow loop
Garden shape
Advanced
Check loop
Drive past wire
3-4
3-4-2
Exit angles
Follow loop
Garden shape
Advanced