Homelite HL80220 Pressure Washer User Manual


 
Page 13 — English
CAUTION:
The use of a pump protector is recommended to prevent
cold weather damage during storage over the winter
months.
MOVING THE PRESSURE WASHER
To move the pressure washer:
Turn the pressure washer off. Point nozzle in a safe direc-
tion and pull trigger to release water pressure.
Store the spray wand on the unit.
Tilt the machine toward you until it balances on the wheels
then roll the machine to the desired position.
For winterizing and long-term storage:
Disconnect the water connection, if necessary.
Start the pressure washer and allow it to run for a few
seconds to eliminate any water remaining in the pump.
Coil the hoses and place in the hook-and loop strap on the
unit’s handle. Do not allow the hose to become kinked.
Store the unit and accessories in an area that does not
reach freezing temperatures. Do not store near furnace or
other sources of heat that could dry out the pump seals.
OPERATION
WARNING:
When servicing, use only identical replacement parts.
Use of any other parts may create a hazard or cause
product damage.
WARNING:
Always wear eye protection marked to comply with
ANSI Z87.1. Failure to do so could result in objects be-
ing thrown into your eyes, resulting in possible serious
injury.
WARNING:
Before inspecting, cleaning or servicing the machine, shut
off engine, wait for all moving parts to stop, and discon-
nect spark plug wire and move it away from spark plug.
Failure to follow these instructions can result in serious
personal injury or property damage.
GENERAL MAINTENANCE
Avoid using solvents when cleaning plastic parts. Most
plastics are susceptible to damage from various types of
commercial solvents and may be damaged by their use. Use
clean cloths to remove dirt, dust, oil, grease, etc.
MAINTENANCE
WARNING:
Do not at any time let brake fluids, gasoline, petroleum-
based products, penetrating oils, etc., come in contact
with plastic parts. Chemicals can damage, weaken or
destroy plastic which may result in serious personal
injury.
Only the parts shown on the parts list are intended to be
repaired or replaced by the customer. All other parts should
be replaced at an authorized service center.
PUMP LUBRICATION
The pump on this unit is lubricated with a sufficient amount
of high grade lubricant for the life of the unit under normal
operating conditions. Therefore, no further lubrication is
required.
G-CLEAN DETERGENT INJECTOR
MAINTENANCE
Before storing the G-Clean detergent injector, rinse to re-
move any detergent residue and allow to dry completely
before reassembly.
POWER SUPPLY CORD REPLACEMENT
If replacement of the power supply cord is necessary, this
must be done by an authorized service center in order to
avoid a safety hazard.