Holder C 9.78 H Lawn Mower User Manual


 
C 9700 ... C 9.88 H
Operating Instructions
194 145 052
Maintenance Every 1500 Service Hours
Checking or Cleaning the Implement Hydraulics
Suction Filter
- Remove the mounting pin (4) of the hydraulic cylinder
(5).
- Remove the banjo screw (3).
- Remove the filter cover fastening screws (2).
- Withdraw the filter housing with the sieve-star filter.
ATTENTION
Observe the instructions for handling fuels
and lubricants.
Cleaning:
- Wash the sieve-star filter with clean Diesel fuel.
Replacement:
- Unscrew the sieve-star filter from the filter housing
with a 24mm open-ended wrench.
- Screw the new filter with a new toroidal sealing ring on
to an the filter housing.
The installation of the suction filter is carried out in the reverse
order of removal.
If an implement variable pump* or power hydraulic system*
is installed, an additional sieve-star filter is installed in the
flange (1). If so, it must also be cleaned or changed as
described above.
Bild_142
5
4
3
2
1
* Option