Pomona, CA Clemmons, NC Nashville, TN
Tel: 908-351-5400 www.haywardpool.com
USE ONLY HAYWARD GENUINE REPLACEMENT PARTS
4
NOTES TO THE ELECTRICIAN:
Useasolidcopperconductor,size8orlarger.Runacontinuouswirefromexternalbondinglugtorein-
forcingrodormesh.ConnectaNo.8AWGsolidcopperbondingwiretothegroundinglugprovidedonthe
heaterandtoallmetalpartsofswimmingpoolorspa,andtoallelectricalequipment,metalpiping(except
gaspiping),andconduitwithin5ft.(1.5m)ofinsidewallsofswimmingpoolorspa.
IMPORTANT-ReferenceNECcodesforallwiringstandardsincluding,butnotlimitedto,grounding,
bondingandothergeneralwiringprocedures.
WARNING – Suction Entrapment Hazard.
Suctioninsuctionoutletsand/orsuctionoutletcoverswhicharedamaged,broken,
cracked,missing,orunsecuredcancausesevereinjuryand/ordeathduetothefol-
lowingentrapmenthazards:
Hair Entrapment-Haircanbecomeentangledinsuctionoutlets.
Limb Entrapment-Alimbinsertedintoanopeningofasuctionoutletorsuctionoutlet
coverthatisdamaged,broken,cracked,missing,ornotsecurelyattachedcanresultina
mechanicalbindorswellingofthelimb.
Body Suction Entrapment-Adifferentialpressureappliedtoalargeportionofthebodyorlimbscan
resultinanentrapment.
Evisceration/ Disembowelment-Avacuumapplieddirectlytotheintestinesthroughanunprotected
suctionoutletsumporsuctionoutletcoverwhichisdamaged,broken,cracked,missing,orunsecured
canresultinevisceration(disembowelment).
Mechanical Entrapment-Thereispotentialforjewelry,swimsuit,hairdecorations,nger,toeorknuck-
letobecaughtinanopeningofasuctionoutletorsuctionoutletcoverresultinginmechanicalentrap-
ment.
WARNING-Toreducetheriskofentrapmenthazards:
• Whensuctionoutletsarelessthana18”x23”equivalent,aminimumoftwofunction-
ingsuctionoutletsperpumpmustbeinstalled.Suctionoutletsinthesameplane(i.e.
oororwall),mustbeinstalledaminimumofthreefeet(3’)[1meter]apart,asmea-
suredfromnearpointtonearpoint.
• Dualsuctionoutletsshallbeplacedinsuchlocationsanddistancestoavoid“dual
blockage”byauser.
• Dualsuctionttingsshallnotbelocatedonseatingareasoronthebackrestforsuch
seatingareas.
• Themaximumsystemowrateshallnotexceedtheowratingofanylisted(percurrentrevisionof
ASME/ANSIA112.19.8)suctionoutletcoverinstalled.
• NeverusethePoolorSpaifanysuctionoutletcomponentisdamaged,broken,cracked,missing,or
notsecurelyattached.
• Replacedamaged,broken,cracked,missing,ornotsecurelyattachedsuctionoutletcomponentsim-
mediately.
• InstalltwoormoresuctionoutletsperpumpinaccordancewithlatestAPSP(formallyNSPI)Stan-
dardsandCPSCguidelines.FollowallapplicableNational,State,andLocalcodes.