3
Installation
Install the connecting tubes
Connect the valves to the spout tee using ⅜" com-
pression ttings (included). Tighten the compression
ttings wrench tight.
Install the rough
Remove the plaster shield, spout adapter and gasket
from the spout tee.
If the mounting surface is unusually, thin, leave the white
plastic spacer in place. Otherwise, it may be removed
and discarded.
Insert the valves and spout tee through the mounting
surface.
Install the stop rings and escutcheon adapters on the
valves. When installed correctly, the stop rings will stop
the escutcheon adapters at the proper mounting height.
Lower the valves so that the escutcheon adapters rest on
the mounting surface.
Slide the spout adapter gasket over the spout tee,
aligning the hole in the gasket with the retaining pin hole
on the mounting surface.
Install the spout adapter.
The retaining pin on the bottom of the
adapter must go through the hole in the
mounting surface.
Tighten the mounting nuts and tensioning screws.
Install the plaster shields. Leave them in place until the
trim is installed.