Shutdown
1. Be sure all detergent is flushed from the system.
2. Turn off the pressure washer at on/off switch on unit.
3. Turn off the water supply.
4. After the motor and water supply are turned off, trigger the gun to depressurize system.
CAUTION: NEVER turn water supply off before turning motor off. Serious damage could occur
to the pump and/or motor.
WARNING!
NEVER disconnect the high-pressure discharge hose from machine while system
is pressurized. To depressurize, turn motor off, turn water supply off and squeeze gun trigger
2-3 times.
5. After each use, wipe all surfaces of the pressure washer with a clean, damp cloth.
Storage
Do not store the pressure washer outdoors. Do not store the pressure washer where it might
freeze. Damage due to freezing is not covered by the warranty.
Major Technical Data
ITEM HP 1400
Working Pressure 7MPa(70 bar)
Working Flow Rate 5.7 l/min
Max. Pressure Water Supply 0.4MPa(4 bar)
Motor Capacity 1650W
Power Supply Voltage 240V~50Hz
Max. Water Temperature 50˚C
Customer Careline: 0845 601 7834
8