6 308-537
Set Up (2340)
If
you are using a downstream chemical injector
, install
it
between the pump unloader and the high pressure
hose,
using the quick couplers provided.
Connect the high pressure hose between the pump
outlet and the gun inlet. Both of these connections are
made
with quick couplers.
CAUTION
Up to 100 ft (30 m) of high pressure hose may
be used.
Longer hoses may af fect sprayer
performance,
and chemical injector
performance,
if
used.
Install the appropriate spray tip on the wand. See
Installing and Changing Spray Tips. If you are using a
sandblaster
kit, see its separate manual for installation
instructions.
Connect to Water Supply
CAUTION
Before attaching to the water supply, check your
local plumbing code regarding
cross–connection
to the water supply . A backflow preventer , P/N
801–133, is available to prevent backflow of
contaminated water into the fresh water supply .
Install
it upstream from the pump.
If inlet water pressure is over 60 psi (4.1 bar) a
regulating water valve, P/N 800–258, must be
installed
at the garden hose connection.
Do not exceed 160 _ F (70 _ C) inlet water
temperature.
Connect
a hose with at least a 3/4 inch (19 mm) ID from
the water supply to the unit’
s
3/4 inch garden hose inlet.
The supply hose should not be more than 50 ft (15 m)
long.
NOTE: The water source at the unit
must
have a
minimum
flow rate
equal to that of the unit (see
Technical
Data, inside back cover).