Graco 3A2573D Log Splitter User Manual


 
Flushing
3A2573D 7
5. Open the gun’s solvent flush valve for gun #1 (B) or
gun #2 (E).
6. Unlock trigger lock and trigger gun into a grounded
pail. Flush out mixed material until clean solvent dis-
penses. Lock trigger lock.
7. Shutoff solvent pump and close solvent valve for
gun #1 (B) or gun #2 (E).
8. Lock trigger lock.
9. Final Flush must be done from the proportioner’s
mix manifold or while flushing your pre-mix sprayer,
through the gun splitter to the gun. Follow Flushing
procedure in your proportioner or sprayer manual.
NOTE: It is good practice to flush through each individ-
ual flush line valve after flushing through the main inlet.
B - OPENE - OPEN
Locked
Unlocked
B - CLOSEE - CLOSE
Locked