Graco 249065 Pressure Washer User Manual


 
9309828
4. Trigger gun until a constant stream of water sprays from tip indicating air is purged from the system.
5. Be sure spark plug ignition cable is pushed firmly onto spark plug.
6. For Model 2525LD ONLY, move
throttle to Rabbit (fast) position first.
For all models, (then) move choke to
CHOKE position.
D Do not allow pressure washer to idle more than 10
minutes. This causes circulating water to overheat and
serious damage to the pump. The pump is equipped
with a thermal valve to help prevent severe damage if
circulating water is overheating.
D Turn off pressure washer if it will not be spraying at
least every 10 minutes or if thermal valve activates. If
heated inlet water is used, reduce this time.
D Do not operate pressure washer with inlet water
screen removed. This screen helps keep abrasive
sediment which could clog pump or damage cylinders,
out of pump.
D Do not pump caustic materials.
CAUTION
7. Pull the starter rope quickly to start the engine. Pull and return the
rope until the engine starts. HINT: Placing one foot on the pres-
sure washer as a brace provides better leverage.
NOTE: For easier starting, have one person start pressure washer while another triggers gun.
ti3240a
ti3242a
Model 2525 Only
All models