Genie 48643 Utility Vehicle User Manual


 
14 Genie IWP Super Series Part No. 48643
Operator’s Manual Second Edition • Fourth Printing
Test Interlock System
9 Pump the foot pedal to raise the base.
Result: The two foot pad display lights should be
off.
10 Pull the base lowering handle to lower the base.
Result: The two foot pad display lights should be
on.
11 Pump the foot pedal to raise the base.
12 Turn both the leveling jacks clockwise to the full
down position.
13 Pull the base lowering handle to lower the
base.
Result: The base will lower and the two level
sensor display lights should be off and remain
off because the base is not level.
14 At the platform controls, push in the control
activate button and rotate the up/down switch to
the UP position, then the DOWN position.
Result: The platform up/down function should
not operate.
Test Emergency Stop
15 Use the bubble level and adjust the leveling
jacks until the machine base is level. Be sure
all four display lights are on.
16 Push in the red Emergency Stop button at the
ground controls.
17 At the platform controls, push in the control
activate button and rotate the up/down switch in
each direction.
Result: The platform up/down function should
not operate.
18 Push in the red Emergency Stop button at the
platform controls and pull out the red
Emergency Stop button at the ground controls.
19 At the platform controls, push in the control
activate button and rotate the up/down switch in
each direction.
Result: The platform up/down function should
not operate.
FUNCTION TESTS
Function Tests
1 Select a level test area free of obstructions.
2 Pump the foot pedal to
raise the base.
Result: The wheels
should contact the
ground.
3 Pull the base lowering
handle to fully lower the
base.
Result: All four foot
pads should come in
firm contact with the
ground.
4 Connect the appropriate power source.
5 Use the bubble level and adjust the leveling
jacks until the machine is level and all four foot
pads are in firm contact with the ground.
6 Insert the key and turn to the ON position OR
turn to platform controls.
7 Pull out the red Emergency Stop button at the
ground controls to the ON position.
8 Twist to release the red Emergency Stop button
at the platform controls.
Result: The power light
should come on. Within
1 to 4 seconds, all four
display lights should turn on
and remain on.