Generac 97193 Portable Generator User Manual


 
Generac Portable Products SVP5000 Generator
7
Stopping the Engine
Unplug all electrical loads from generator panel
receptacles. Never start or stop engine with
electrical devices plugged in and turned on.
Let engine run at no-load for several minutes to
stabilize the internal temperatures of engine and
generator.
Move engine control switch to the Off position.
Close the fuel shutoff valve.
COLD WEATHER
OPERATION
Under certain weather conditions (temperatures below
40°F [4°C] and a high dew point), your Generac
generator may experience icing of the carburetor
and/or the crankcase breather system.
In an emergency, use the original shipping box as a
temporary shelter:
Cut off all flaps.
Cut out one of the long sides of the box to expose
exhaust side of unit. Ensure a minimum of two feet
clearance between open side of box and nearest
object.
Cut appropriate slots to access receptacles of unit.
You may also need to cut a clearance slot for the
handle.
Start unit, then place box over it.
IMPORTANT: Remove shelter when temperature is
above 40°F [4°C].
For a more permanent shelter, build a structure that
will enclose three sides and the top of the generator:
Make sure entire muffler-side of generator is
exposed. A typical shelter is shown in Figure 6.
Ensure a minimum of two feet clearance between
open side of box and nearest object.
Face exposed end away from wind and elements.
Enclosure should hold enough heat created by the
generator to prevent icing problems.
CAUTION! Never run unit indoors; Do Not
enclose generator any more than shown.
Remove shelter when temperatures are above
40°F [4°C].
Figure 6  Typical Cold Weather Temporary Shelter
Wind