TROUBLESHOOTING
Problem
Engine is running, but
no AC output is
available.
Engine runs good but
bogs down when
loads are connected.
Cause
1. Circuit breaker is open.
2. Poor connection or defective cord set
3. Connected device is bad
4. Fault in generator.
1. Short circuit in a connected load.
2. Generator is overloaded.
3. Engine speed is too slow.
4. Shorted generator circuit.
1. Run/Stop switch set to"Stop".
2. Dirty air cleaner.
3. Out of gasoline.
4. Stale gasoline.
5. Spark plug wire not connected to
Solution
1. Reset circuit breaker.
2. Check and repair.
3. Connect another device that is in
good condition.
4. Contact Generac service facility.
1. Disconnect shorted electrical load.
2. See "Don't Overload the GeneratoY'
on page 11.
3. Contact Generac service facility.
4. Contact Generac service facility.
1. Set switch to "Run".
2. Clean or replace air cleaner.
3. Fill fuel tank.
4. Drain gas tank and fill with fresh
fuel.
5. Connect wire to spark plug.
Engine will not start;
or starts and runs
rough,
spark plug.
6. Bad spark plug.
7. Water in gasoline.
8. Overchoking.
9. Low oil level.
10.
11.
12.
Excessively rich fuel mixture.
Intake valve stuck open or closed.
Engine has lost compression.
6. Replace spark plug.
7. Drain gas tank; fill with fresh fuel.
8. Put choke lever at "No Choke"
position.
9. Fill crankcase to proper level,
10. Contact Generac service facility,
11. Contact Generac service facility,
12. Contact Generac service facility,
Engine shuts down
during operation.
Engine lacks power.
Engine "hunts" or
falters.
1. Out of gasoline.
2. Low oil level.
3. Fault in engine.
1. Load is too high.
2. Dirty air filter.
3. Engine needs to be serviced.
1. Choke is opened too soon.
2.
Carburetor is running too rich or too
lean.
1. Fill fuel tank.
2. Fill crankcase to proper level.
3. Contact Generac service facility,
1. See"Don't Overload the GeneratoP
on page 11.
2. Replace air filter.
3. Contact Generac service facility.
1. Move choke to halfway position till
engine runs smoothly.
2. Contact Generac service facility,
/
13