Figure 2.7 – Typical Noise Abatement
2.2.5 COMPARTMENT FLOOR CUTOUTS
You must provide openings in the generator compart-
ment for the following items (Figure 1.2, page 21):
• Engine exhaust and cooling air outlets
• Generator cooling air inlet
• Four holes for passage of generator mounting
bolts. See Section 2.1.4 (Page 23).
Fuel lines and exhaust piping must not pene-
trate into the vehicle living area.
!