Gardena Art. 1559 Irrigation System User Manual


 
16
GB
If the watering pattern is no longer even, the nozzles can be
cleaned using the cleaning needle provided.
1. Open both locks
A
and raise the cover
B
.
2. Turn the cleaning needle
D
(e.g. with a coin) anticlockwise
through 180° 1 and pull out
carefully 2 (bayonet coupling).
3. Clean nozzles
E
with cleaning
needle
D
.
4. Refit cleaning needle
D
in
reverse order.
5. Close cover
B
and both
locks
A
.
To make sure that the rechargeable battery is always sufficiently
charged, the protective panel of the solar cell has to be cleaned
if soiled.
No caustic /abrasive cleaning agents or hard objects should
be used.
v Clean protective panel of solar cell with a damp cloth.
8. Troubleshooting
Fault Possible cause Remedy
Irrigation width smaller than Dirt filter soiled. v Clean dirt filter.
on initial start-up
Tap not opened sufficiently. v Open tap further.
Water pressure too low. v Increase water pressure /
water supply.
Rechargeable batteries almost v Ensure solar cells are
flat (Auto and Set LED flashing)/ exposed to sufficient
Protective panel of solar cells sunlight /clean protective
soiled. panel. If the rechargeable
battery is almost flat, the
range is reduced to the
min. level.
Large-area pop-up irrigation v Press OK button.
is in energy-saving mode
(4 weeks without energy
supply or operation).
Irrigation range is programmed v Reprogramme irrigation
incorrectly. range.
Watering pattern uneven Nozzles soiled. v Clean nozzles.
Nozzle head soiled. v Clean nozzle head.
Nozzle head damaged. v Contact GARDENA Service.
Auto and Set LED flashing Rechargeable batteries almost v Ensure solar cell is exposed
simultaneously discharged. to sufficient sunlight.
Clean nozzles:
Clean protective panel of
solar cell:
E
D
A
B
D