Gardena 1559 Irrigation System User Manual


 
13
GB
Select watering sector:
Install Large-Area Pop-Up
Irrigation:
Incorrect location:
1:
No obstacles (e.g. walls, trees, etc.) should be located in the
watering sector. It must be possible to access every contour
point of the areas to be watered in a straight line. With the
maximum range the spray height can reach approx. 5 m.
2:
The minimum range is 2.5 m (at 2 bar).With circle water
distribution the large-area pop-up irrigation must therefore be
located 2.5 m from the edge in all directions (A). If this is not
possible the large-area pop-up irrigation should be positioned
at the edge and the watering area will be a circle sector (B).
Before installing the large-area pop-up irrigation, you must
set up an above-ground test to check whether the large-
area pop-up irrigation can actually water the required area
at this location.
The large-area pop-up irrigation has a 3/4 female thread and is
connected to the 25 mm Connecting Pipe
8
Art. 2700 / 2701
using the GARDENA L-piece
7
Art. 2781.
1. Install the above-ground test set-up and check whether the
large-area pop-up irrigation can water the required area (see
5. Operation).
2. If the large-area pop-up irrigation has watered the required area
in the test, install a pack of coarse gravel
9
approx. 20 cm x 20
cm x 20 cm in size underneath the unit.
This ensures proper functioning of the drain valve.
3. Install the upper edge of the large-area pop-up irrigation level
with the turf.
This prevents any damage when mowing the lawn.
v Take off transportation protective plastic film from the protective
panel of of the solar cell.
5. Operation
A watering sector from 25° to 360° can be selected.To prevent
areas being watered unintentionally (e.g. house), the sector
should first be selected roughly (slightly too small).
Roughly select sector:
1. Close water supply.
2. Turn the nozzle head
0
by hand to the middle of the watering
sector (e.g. P4).
3. Roughly select watering sector: turn right sector stop
z
R
to
right-hand side (e.g. P9) and left sector stop
z
L
to left-hand side
(e.g. P2).
Re-adjust sector:
1. Open water supply.
2. Watch watering sector and re-adjust the sector-stops
z
L
and
z
R
according to the sector limits (P1 and P10) until the change in
direction matches the required irrigation limits.
If watering in a complete circle, the two sector stops
z
L
and
z
R
must be completely pushed together between P1 and P10.
Remove protective plastic
film of solar cell:
0
z
L
z
R
8 7 9