CABLES
IMPORTANT
Use only 1.00mm
2
size cable up to 40 metres length
maximum.
Maximum rating :
1.00mm
2
size cable, 10 amps 250 volts AC.
YOUR HEDGETRIMMER IS SUPPLIED WITH
CABLE WIRED DIRECTLY INTO THE PRODUCT.
1. Mains Cables and Extension Cables are available
from your local Approved Service Centre.
2. Do not wire an extension cable directly to your
product yourself. Please contact your local Approved
Service Centre for further information on the
connectors and kits available.
3. Only use extension cables specifically designed for
outdoor use.
CONNECTORS
IMPORTANT
Connectors are suitable for use with 2 core cable
only. Under no circumstances should these
connectors be used for earthed products.
All connectors and cables are of splashproof
construction. They are not waterproof and must not
be left outside permanently nor should they be
submerged or immersed in water. Do not let cable lay
or trail through pools of water or splashed with water
from hose pipes.
MAINS PLUG REPLACEMENT
IMPORTANT
If the plug supplied is cut off it should be destroyed.
There is an electric shock hazard if a cut off plug is
inserted into a 13 amp socket.
1. No earth required. Our products are double insulated
to EN60745 and under no circumstances should an
earth be connected to any part of the product.
2. Ensure the mains voltage suits your product
3. IMPORTANT!
The wir
es in the mains lead are coloured in
accordance with the following code:
BLUE - NEUTRAL
BROWN - LIVE
The wire which is coloured BLUE must be connected
to the Terminal which is marked with the letter 'N' or
coloured BLACK.
The wire which is coloured BROWN must be
connected to the Terminal which is marked with the
letter 'L' or coloured RED.
4. It is important that the outer sheath is clamped
correctly into the 3-pin plug.
5. If in doubt consult your local Service Repairer or
qualified electrician before the machine is used.
6. A 13 Amp fuse must be fitted to the Mains Plug.
7. The normal plug fuse and household fuse only protect
the electrical equipment and are not a safeguard
against electrocution.
If your product is hard wired i.e. non-detachable
mains electric cable, a conversion kit and extension
cable is available from all Approved Service Centres
which can be found in your local Yellow Pages.
Assembly of Handguard.
1. Insert Handguard into slot as illustrated in figure A,
ensuring that it is securely located.
DO NOT USE THE PRODUCT WITHOUT FITTING
THE HANDGUARD
Assembly
A
Cables