Fisher 244EH Weather Radio User Manual


 
Rosemount Models 244EH and 244ER PC-Programmable Temperature Transmitters
A-6
ORDERING INFORMATION
TABLE A-4. Model 244EH and 244ER Temperature Transmitter Ordering Information
= Available
— = Not available
Model Product Description
Head
Mount
Rail
Mount
244EH Head Mount Temperature Transmitter
244ER Rail Mount Temperature Transmitter
Code Hazardous Area Certifications
Enclosure Purchase
Required?
Head
Mount
Rail
Mount
E5 FM Explosion-Proof Approval Ye s
I5 FM Intrinsic Safety and Non-Incendive Approval No*
K5 FM Intrinsic Safety, Non-Incendive, and Explosion-Proof Approval Combination Ye s
I6 CSA Intrinsic Safety and Non-Incendive Approval No*
C6 CSA Intrinsic Safety, Non-Incendive, and Explosion-Proof Approval Combination Ye s
N1 CENELEC/BASEEFA Type n Approval Ye s
ED CENELEC/KEMA Flameproof Approval Ye s
I1 CENELEC/BASEEFA Intrinsic Safety Approval No*
E7 SAA Flameproof Approval.
Consult factory for availability.
Ye s
N7 SAA Type N Approval.
Consult factory for availability
Ye s
I7 SAA Intrinsic Safety Approval.
Consult factory for availability.
No*
NA No Approval No*
* Transmitters with intrinsic safety approvals can be ordered without enclosures. However, to meet intrinsic safety requirements, the transmitter must be installed in
an enclosure with IP20 or higher rating. Model 244EH transmitters ordered with enclosure options J5 or J6 meet this requirement.
Code Options
Assembly Options (Model 244EH Only)
X1 Assemble Transmitter to a Sensor Assembly (hand tight,
Tefl on
®
(PTFE) tape where appropriate, fully wired)
X2 Assemble Transmitter to a Sensor Assembly (hand tight, no
Tefl on
(PTFE) tape, unwired)
X3 Assemble Transmitter to a Sensor Assembly (wrench tight,
Te f lon
(PTFE) where appropriate, fully wired)
Note: If ordering X1, X2, X3, specify the same code on the sensor model number.
Option codes X1 and X3 are not available with CSA Approvals (Hazardous Area Certifications C6 or I6)
Enclosure Options
Threaded Style Temperature Sensor Users (Americas and Asia Pacific)
Remote/Integral Mount
J6 Universal Head (Junction Box), Aluminum Alloy with 2-in. SST Pipe Bracket (M20 Entries)
DIN Plate Style Temperature Sensor Users (EMEA-Europe, Middle East, and Africa)
Remote Mount
J5 Universal Head (Junction Box), Aluminum Alloy with 2-in. SST Pipe Bracket (M20 Entries)
J6 Universal Head (Junction Box), Aluminum Alloy with 2-in. SST Pipe Bracket (
1
/2–14 NPT Entries)
Integral Mount
*****Order connection head through Volume 2 of the Rosemount Temperature Sensor and Accessories Product Data Sheet
(document number 00810-0101-2654) sensor model number*****
Configuration Options
A1 Analog Output Levels Compliant with NAMUR-Recommendations NE 43:June 1997
CN Analog Output Levels Compliant with NAMUR-Recommendations NE 43: June 1997: Alarm Configuration Low
F6 60 Hz Line Voltage Filter
Calibration Options
C4 5-Point Calibration.
Use Q4 option to generate a calibration certificate
Q4 Calibration Certificate.
3-Point standard; use C4 with Q4 option for a 5-point calibration certificate.
Accessory Options (Model 244EH only)
G1 External Ground Screw.
Only available with enclosure options J5 or J6
.
G2 Cable Gland.
Only available with option code J5.
G3 Cover Chain.
Only available with enclosure options J5 or J6. Not available with LCD meter option code M5.
G5
WAGO
Spring Clamp Terminals
Typical Model Number – Americas and Asia Pacific: 244EH E5 X1 J6 F6
Typical Model Number – Europe, Middle East, Africa: 244EH ED X1