Echo PB-650 Blower User Manual


 
11
POWER BLOWER
OPERATOR'S MANUAL
OPERATION
Recoil starter: Use short pulls - only 1/2-2/3 of rope length for
starting. Do not allow the rope to snap back in. Always hold the unit
firmly.
Rotate spring loaded throttle handle downward to a comfortable
operating position.
STARTING COLD ENGINE
1. Move throttle lever (A) to START/IDLE DETENT position.
2. Close Choke - Cold Start.
Move choke (B) up to "Cold Start" position.
3. Primer Bulb -Prime.
Pump primer bulb (D) until fuel is visible and flows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
4. Pull recoil starter handle (D) until engine fires (5 or 6 pulls).
5. Move choke (B) to run position and if necessary, restart engine.
NOTE
If engine does not start after 5 pulls, use cold start procedures.
NOTE
Allow engine to warm up before use.
STARTING WARM ENGINE
1. Move throttle lever (A) to start/idle detent position.
2. Pull recoil starter handle (D) and engine should start. Do not use
choke (B).
NOTE
If engine does not start after 5 pulls, use cold start procedures.
A
B
C
D