Echo PB-500H Blower User Manual


 
17
Po w e r Bl o w e r
oP e r a t o r 's Ma n u a l
s t a r t I n g
w a r m e n g I n e
The starting procedure is the same as Cold Start except DO NOT close
the choke.
PB-500H
1. Throttle Lever
Move throttle position lever (A) midway between idle and full
throttle positions.
PB-500T
1. Throttle Position / Stop Switch Button
Slide Throttle position / Stop switch Button(A) back to idle posi-
tion.
PB-500H, PB-500T
2. Purge Bulb
Pump purge bulb (D) until fuel is visible and ows freely in the
clear fuel tank return line. Pump bulb an additional 4 or 5 times.
3. Recoil Starter
Pull recoil starter handle (E) and engine should start. Do not use
choke (C).
NOTE
If engine does not start after 5 pulls, use cold start procedures.
s t o p p I n g e n g I n e
PB-500H
1. Throttle Lever
Move throttle lever (A) to IDLE DETENT position and allow
engine to return to idle before shutting off engine.
2. Throttle Lever
Move throttle lever (A) to "O" (Stop) position.
PB-500T
1. Throttle Position / Stop Switch Button
Release throttle trigger. Move Throttle Position / Stop Switch But-
ton (A) forward to idle position and allow engine to return to idle
before shutting off engine.
2. Throttle Position / Stop Switch Button
Move Throttle Position / Stop Switch Button (A) all the way for-
ward to STOP position.
WARNING
If engine does not stop when stop switch is moved to STOP posi-
tion:
• Be certain engine is at idle, otherwise engine may continue to
run.
• Close choke - COLD START position - to stall engine.
• Have your ECHO dealer repair stop switch before using blower
again.
PB-500H
PB-500H
PB-500T
A
PB-500T
A
E
C
D