Dixon 7500 Series Lawn Mower User Manual


 
31
CARE AND MAINTENANCE
HYDROSTAT OIL MAINTENANCE PROCEDURE:
Check the oil level in hydrostatic transmisison oil
reservoir after every 25 hours of usage. Clean the oil
reservoir cap and the area around it prior to removal.
Check the oil level. Oil should be approximately 1-3/8”
below top of oil tank. Replenish as needed with SAE
20W-50 motor oil. DO NOT OVERFILL. When
checking the oil level, be very careful to keep the
reservoir clean.
Change the oil in the reservoir and hydrostat
transmission oil filter after the first 100 hours of use.
Then every 500 hours after that. Remove the filter and
be sure all oil has drained from the reservoir. Replace
with a new filter and SAE 20W-50 motor oil.
Please dispose of used oil at proper collection centers -
protect your environment
Fuel Cap
Sight Slot
Oil Reservoir Cap