CARE AND MAINTENANCE - 5000 SERIES MODELS
FUEL SHUT OFF VALVE:
A fuel shut off valve is located at the bottom rear of each fuel tank.
Always turn the valve to the "OFF" position when the mower is stored or not in use.
LUBRICATION
CHASSIS:
Number of grease zerks used: (7)
LOCATIONS:
(1) each front wheel caster and each front wheel hub
(1) each mower deck shaft
SERVICE INTERVALS:
Every 50 hours of operation
RECOMMENDED GREASE:
Name brand wheel bearing or multi-purpose grease
Rotate or spin each f
ront wheel after 3 full pumps of the grease
gun. Repeat until the appearance of grease is noted around
each caster. Lubrication of the mower deck shafts will help
dispel moisture within the hub casting. Bearings are of a sealed
design.