DeVillbiss Air Power Company D25572 Portable Generator User Manual


 
15- ENG
D25572
CONNECTING PROCEDURE FOR RAISING OR SUSPENDING
GENERATORS EQUIPPED WITH LIFT RINGS
Failure to properly connect lifting cables, chains, or straps
can cause property damage, serious injury or death, and
void the manufacturer's warranty.
Always use cables, chains, or straps rated at 2000 lbs.
working load or more to raise or suspend generator.
Never operate generator while suspended. This could
cause property damage, serious injury or death.
1. Route cable, chain, or strap through
both lift rings as shown. ALWAYS
use both lift rings when raising or
suspending generator.
NOTE: Make sure the generator is in a
level position before raising or suspend-
ing to prevent damage.
Lift Ring
Lift Ring
Note 1: Change oil after first two (2) operating hours and every 50 operating
hours thereafter, more often if operated in extreme dusty or dirty conditions.
Note 2: Check oil after 5 hours of operation.
CUSTOMER RESPONSIBILITIES TABLE
MAINTENANCE TASK
Before
each
use
Every 25
Hours of
Every
Season
Every 50
Hours of
Every
Season
Every 100
Hours of
Every
Season
Check Spark Plug
Prepare unit for storage if it is to remain
idle for more than 30 days.
MAINTENANCE
Check oil level
Change oil
Clean Air Filter Assembly
Prepare Unit for Storage
See Note 2
X
See Note 1
X
X
X
GENERAL RECOMMENDATIONS
The warranty of the generator does not cover items that have been subjected to
operator abuse or negligence. To receive full value from the warranty, operator
must maintain the generator as instructed in this manual.
ENGINE MAINTENANCE
Refer to the Engine Operator's manual for service and maintenance of the
engine.