WARNING: Improper installation, adjustment, al-
teration, service, or maintenance can cause injury or
property damage. Only a qualified electrical service
person should service and repair generator.
• Generator produces high voltage. Use extreme
caution when working on electrical parts.
• Turn off generator and let cool before installation.
Severe burns may result.
• Remove spark plug wire from spark plug before
installation. This will prevent accidental starting.
• Use only factory-approved replacement parts.
Figure 2 - Engine Key Switch
Figure 1 - Auto-Idle Switch Location
Auto-Idle Switch
(Rocker Switch)
Key Switch
Notice:
The 250 volt/50 amp receptacle is not connected through the
auto-idle circuit. Auto-idle rocker switch must be turned off to get
full power out of this receptacle (see Figure 1).
250 volt/50 amp
receptacle
STARTING
IMPORTANT:
The loaded engine speed is preset. The throttle is
locked in preset position. Do not adjust throttle. Preset position lets
engine run at 3600 RPM under load. The engine must maintain 3600
RPM for generator to create correct voltage. Running engine at
lower speeds will damage generator and powered items.
IMPORTANT:
Never start generator with electrical loads con-
nected. Start engine before adding electrical loads.
OPERATION INSTRUCTIONS
1. If the engine is cold, turn Auto-Idle switch off (see Figure 1).
2. Start Engine. Allow engine to warm up with no load for five
minutes.
3. Turn Auto-Idle switch on. Engine will slow to idle speed. En-
gine idle speed is preset. Idle speed adjustment should not be
necessary.
4. Operate generator according to specifications outlined in
owner’s manual.
5. Engine will automatically increase to normal operating speed
when you plug load into any generator outlet.
6. Auto-Idle system should be turned off when generator is shut
down.
WARNING: Only responsible adults should use
generator. Never let anyone operate generator with-
out proper instructions.
PRESTART
Operate generator on a firm, dry, and clean surface. The surface must
be level. Protect generator from heavy dust, sand, dirt, rain, or snow.
Do not locate generator near standing water and snow. Make sure
area is well-vented.
Note:
If oil level is too low, oil alert system will keep engine from
starting (see Oil Alert System in owner’s manual, page 8). Make sure
oil level is full before starting. See Engine Oil in owner’s manual,
page 8.
Before starting the engine, disconnect all electric loads from generator.
STOPPING ENGINE
IMPORTANT:
The loaded engine speed is preset. The throttle is
locked in preset position. Do not adjust throttle.
Follow the steps below to stop engine.
1. Remove all electrical loads from generator (see Disconnecting
Electrical Loads in owner’s manual, page 13). Remove elec-
trical loads one at a time.
2. Let engine run for two or three minutes after removing electri-
cal loads. This lets engine cool slightly.
3. Turn engine key switch to the OFF position (see Figure 1).
4. Turn fuel valve off. Do this by rotating valve, located under
fuel tank, clockwise to the horizontal position (see Figure 3).