Craftsman 580.327071 Portable Generator User Manual


 
OPERATION
KNOW YOUR GENERATOR
READ THIS OWNER'S MANUAL AND SAFETY RULES BEFORE OPERATING YOUR GENERATOR, Compare the
illustrationswith your generator, to familiarize yourself withthe locations of various controls and adjustments, Save this
manual for future reference
AC CIRCUIT BREAKERS
ENGINE RUN/STOP SWITCH
IDLE CONTROL SWITCH
12VOLT, t0AMP
BATTERY CHARGE
RECEPTACLE
120VOLTS"DUPLEX"
RECEPTACLES
120VOLTS, 20
RECEPTACLE
120VOLTS, 30AMi
RECEPTACLE
12(_240VOLTS, 30AMP
RECEPTACLE
240VOLTS, 50 AMP
RECEPTACLE
CLEANER
V-TWIN ENGINE
RLTER
ENGINE RUN/STOP SWITCH -- Must be set to RUN to
start the engine Set switch to STOP to stop the engine
120 VOLTS "DUPLEX" RECEPTACLES -- May be used
to suppIy electrical power for the operation of 120 voits at
20 amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads
120 VOLTS, 30 AMP RECEPTACLE -- May be used to
supply electrical power for the operation of 120 volts at 30
amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tooi and motor ioads Twistlock connectors are
required when using this receptacle
120 VOLTS, 20 AMP RECEPTACLE -- May be used to
supply electrical power for the operation of 120 volts at 20
amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads Twistlock connectors are
required when using this receptacle
120/240 VOLTS RECEPTACLE -- May be used to supply
electrical power for the operation of up to 240 volts at 30
amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads Twist]ock connectors are
required when using this receptacle
AC CIRCUIT BREAKERS -- Protects the generator
against electrical ovedoad Breakers are "push to reset"
type for 15-amp, 20-amp and 30-amp loads.
SPARK ARRESTOR MUFFLER -- Exhaust muffter has a
spark arrestor screen
240 VOLTS, 50 AMP RECEPTACLE -- May be used to
supply electrical power for the operation of up to 240 volts
at 50 amps AC, single phase, 60 Hz, AC electrical lighting,
appliance, tool and motor loads Range connectors are
required when using this receptacle
FUEL LEVEL GAUGE - Indicates level of fuel in fuel tank