Country Home Products 6-TON Log Splitter User Manual


 
CALL TOLL FREE 1-800-DR-OWNER 23
CHAPTER 6
TROUBLESHOOTING
Consult the Troubleshooting Table below for common problems and their solutions. If you continue to
experience problems, call our Technical Support Representatives at 1-800-DR-OWNER.
Troubleshooting Table
BEFORE PERFORMING ANY MAINTENANCE, YOU MUST UNPLUG THE WOOD SPLITTER FROM THE
POWER SOURCE. MAKE SURE THE HYDRAULIC SYSTEM IS DEPRESSURIZED (SEE PAGE 7), AND MAKE
SURE THE FLUID HAS COOLED.
READ THE "GENERAL SAFETY RULES" (CHAPTER 2) OF THIS MANUAL BEFORE PERFORMING ANY
REPAIRS OR MAINTENANCE.
SYMPTOM POSSIBLE CAUSE
Ram will not move
or is slow to
respond.
The Air Bleed Screw may be open. See page 13, Step 3.
The motor Reset has tripped; push the Reset Button. See Figure 1 on page 10.
Bleed any accumulated air from the hydraulic system. See page 20, step 5.
The wood splitter may not be on a level surface. See page 13, step 1.
Make sure the voltage at the outlet or extension cord connection to the wood splitter
is at least 105VAC.
If you are using an extension cord, make sure that the cord is less than 33 feet long
and is not smaller than 12 AWG wire.
The hydraulic fluid may be low. Check and adjust the level as required; see page 20.
In extreme high temperature and heavy rapid use, the hydraulic fluid may have over
heated. Allow the machine to cool.
The wood you are splitting may be too hard, it has knots, or its fiber is very tough.
Log fails to split.
Check the possible causes for the previous Ram operation symptom.
Incorrect positioning of the log; re-position the log flat on the splitting beam with
the ends squarely against the Ram face and Splitting Wedge.
Log exceeds permitted dimensions or the wood is too hard for the capacity of the
machine. The maximum log length is 20" with a maximum diameter of 16" for the
DR 6 -TON ELECTRIC WOOD SPLITTER.
The wedge has burrs or nicks and needs to be sharpening; see page 20.
There may be a hydraulic fluid leak. Locate the leak using a piece of cardboard
under the machine and call 1-800-DR-OWNER (376-9637), or a qualified hydraulic
mechanic for assistance, to replace worn components.
Hydraulic pressure is too low. Call 1-800-DR-OWNER (376-9637), or a qualified
hydraulic mechanic for assistance to replace worn components.